  1.  GENERAL
    1. SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

      1. Residential elevators of the following types:
        1. Builders Series residential elevator.
        2. Transcend Series residential elevator.
    1. RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

      1. Section 05 50 00 – Metal Fabrications.
      2. Section 14 21 00 – Electric Traction Elevators.
      3. Section 14 42 13 – Inclined Wheelchair Lifts.
      4. Section 26 05 00 – Common Work Results for Electrical.
    1. REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

      1. Elevator shall be designed, manufactured and installed in accordance with the following standards:
        1. American National Standards Institute (ANSI).
        2. American Society of Mechanical Engineers (ASME).
        3. International Building Code (IBC).
        4. National Electrical Code (NEC).
        5. American Society for Testing Materials (ASTM).
        6. American Welding Society (AWS).
    1. SUBMITTALS
      1. Submit under provisions of Section 01 30 00 – Administrative Requirements.
      2. Product Data:
        1. Manufacturer’s data sheets on each product to be used.
        2. Preparation instructions and recommendations.
        3. Storage and handling requirements and recommendations.
        4. Typical installation methods.
      3. Verification Samples: For each finish product specified, two samples, minimum size 2 inches (51 mm) square representing actual product, color, and patterns.
      4. Shop Drawings: Include details of materials, construction and finish. Include relationship with adjacent construction.
    2. QUALITY ASSURANCE
      1. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section with a minimum five years documented experience.
      2. Installer Qualifications: Company specializing in performing Work of this section with minimum two years documented experience with projects of similar scope and complexity.
        1. Installers shall be experienced in performing work of this section who have specialized in work comparable to that required for this project.
        2. Installers shall be certified and trained by the manufacturer.
      3. Source Limitations: Provide each type of product from a single manufacturing source to ensure uniformity.
    3. PRE-INSTALLATION CONFERENCE
      1. Convene a conference approximately two weeks before scheduled commencement of the Work. Attendees shall include Architect, Contractor and trades involved. Agenda shall include schedule, responsibilities, critical path items and approvals.
    4. DELIVERY, STORAGE, AND HANDLING
      1. Store and handle in strict compliance with manufacturer’s written instructions and recommendations.
      2. Protect from damage due to weather, excessive temperature, and construction operations.
    5. PROJECT CONDITIONS
      1. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer’s recommended limits.
    6. SEQUENCING
      1. Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.
    7. WARRANTY
      1. Manufacturer’s Warranty: Provide manufacturer’s standard limited warranty.
      2. Warranty: Manufacturer shall warrant component parts of the Elevations home elevator for a period of three years after installation.
  1.  PRODUCTS
    1. MANUFACTURERS
      1. Acceptable Manufacturer: Rocky Mountain Elevator Products, which is located at: 416 29 Rd.; Grand Junction, CO 81504; Tel: 970-242-2544 ; Fax: 970-241-7377; Email: request info (info@rmep.us); Web: https://www.rockymountainelevatorproducts.com

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

      1. Substitutions: Not permitted.
      2. Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 – Product Requirements.
    1. SYSTEM
      1. System Description:
        1. The products described herein, manufactured by Rocky Mountain Elevator Products, is a private residence home elevator designed and dimensioned to provide access to all levels to the home based on the individual’s requirements.
        2. Designs, clearances, workmanship and material, unless specifically accepted, shall be in accordance with all codes having legal jurisdiction.
        3. Load ratings and safety factors shall meet or exceed those specified by all governing agencies with jurisdiction and shall be certified by a professional engineer.
        4. Elevator shall be subject to applicable state, local and city approval prior to installation and subject to inspection after installation. Determination of and adherence to these regulations is the responsibility of the elevator contractor.
        5. Welders certified in accordance with requirements of AWS D1.1 shall perform all welding of all parts.
    2. ELEVATOR

** NOTE TO SPECIFIER ** Designed for beauty on a budget. Wood cabs trimmed in engineered woods to hand crafted hardwoods. Delete if not required.

      1. Provide Builder’s Series home elevator manufactured by Rocky Mountain Elevator Products:
        1. The Builders Series is a wood constructed car.

** NOTE TO SPECIFIER ** Delete if not required.

      1. Provide Transcend Glass Series home elevator manufactured by Rocky Mountain Elevator Products:
        1. The Transcend Series is an aluminum framed constructed car.

** NOTE TO SPECIFIER ** Delete if not required.

    1. RESIDENTIAL ELEVATOR – BUILDERS SERIES
      1. System: Provide Builder’s Series home elevator by Rock Mountain Elevator Products.
      2. Characteristics:

** NOTE TO SPECIFIER ** Delete drive system not required.

        1. Drive System: Provide a hydraulic system (SRH).
        2. Drive System: Provide a machine room less hydraulic system (MRL).
        3. Drive System: Provide a floor mount winding drum system (RMR).
        4. Drive System: Provide a machine room less winding drum system (RMD).

** NOTE TO SPECIFIER ** Delete stops not required.

        1. Number of Stops: 2.
        2. Number of Stops: 3.
        3. Number of Stops: 4.
        4. Number of Stops: 5.
        5. Number of Stops: 6.

** NOTE TO SPECIFIER ** Delete car configuration not required.

        1. Car Configuration: Front – enter and exit same side.
        2. Car Configuration: Front and Rear – enter and exit opposite sides.
        3. Car Configuration: Front and Side – enter and exit 90 degree adjacent sides.

** NOTE TO SPECIFIER ** Specify maximum travel up to 50 feet (15.24 m)

        1. Maximum Travel: ___.

** NOTE TO SPECIFIER ** Delete rated load not required. 1400 pound capacity may require local code variance.

        1. Rated Load: 750 pounds (340Kg).
        2. Rated Load: 950 pounds (430 Kg).
        3. Rated Load: 1400 pounds (635 Kg).
        4. Rated Speed: 40 FPM (12.2 MPM).

** NOTE TO SPECIFIER ** Delete car size not required.

        1. Car Size: 36 inches W x 48 inches D (914 mm x 1219 mm).
        2. Car Size: 36 inches W x 60 inches D (914 mm x 1524 mm).
        3. Car Size: 40 inches W x 54 inches D (1016 mm x 1372 mm).

** NOTE TO SPECIFIER ** Delete car height not required.

        1. Car Height: 80 inches (2032 mm).
        2. Car Height: 84 inches (2134 mm).
        3. Car Height: 96 inches (2438 mm).

** NOTE TO SPECIFIER ** Delete car wall material and design not required.

        1. Car Walls: Flat panel laminate. Engineered wood with laminate finish.

** NOTE TO SPECIFIER ** Delete laminate not required.

          1. Laminate: Light oak (standard).
          2. Laminate: Antique White (standard).
          3. Laminate: White.
          4. Laminate: Beige.
          5. Laminate: Black.
          6. Laminate: Birch.
          7. Laminate: Oak.
          8. Laminate: Walnut.
          9. Laminate: Cherry.
          10. Laminate: Mahogany.
        1. Car Walls: Flat panel wood veneer. Unfinished plywood veneer.

** NOTE TO SPECIFIER ** Delete veneer not required.

          1. Veneer: Birch (standard).
          2. Veneer: White Oak (upgrade).
          3. Veneer: Red Oak (upgrade).
          4. Veneer: Walnut (upgrade).
          5. Veneer: Mahogany (upgrade).
          6. Veneer: Cherry (upgrade).
          7. Veneer: Maple (upgrade).
          8. Veneer: Clear Alder (upgrade).
          9. Veneer: Knotty Alder (upgrade).
        1. Car Walls: Hardwood wall panels. Handmade from dimensional lumber.

** NOTE TO SPECIFIER ** Delete panel not required.

          1. Panel: Shaker 2 panel.
          2. Panel: Raised 2 panel.
          3. Panel: Raised 4 panel.
          4. Panel: Raised 6 panel.
          5. Panel: Recessed 2 panel.
          6. Panel: Recessed 4 panel.
          7. Panel: Recessed 6 panel.

** NOTE TO SPECIFIER ** Delete species not required.

          1. Species: Birch (upgrade).
          2. Species: White Oak (standard).
          3. Species: Red Oak (upgrade).
          4. Species: Mahogany (upgrade).
          5. Species: Cherry (upgrade).
          6. Species: Maple (upgrade).
          7. Species: Clear Alder (upgrade).
          8. Species: Knotty Alder (upgrade).
          9. Species: Walnut (upgrade).

** NOTE TO SPECIFIER ** Delete ceiling not required.

        1. Ceiling: Match car panels (standard).
        2. Ceiling: Single tray with crown molding.
        3. Ceiling: 4 panel with crown molding.
        4. Ceiling: 4 panel recessed.
        5. Ceiling: 4 panel raised.
        6. Ceiling: Antique White laminate.

** NOTE TO SPECIFIER ** Delete car lighting standard options not required.

        1. Car Lighting: 2 – 3 inch (76 mm) LED white trim.
        2. Car Lighting: 2 – 3 inch (76 mm) LED black trim.
        3. Car Lighting: 2 – 3 inch (76 mm) LED brushed stainless steel trim.
        4. Car Lighting: 2 – 3 inch (76 mm) LED oil rubbed bronze trim.

** NOTE TO SPECIFIER ** Delete car lighting upgrade options not required.

        1. Car Lighting: 4 – 3 inch (76 mm) LED white trim.
        2. Car Lighting: 4 – 3 inch (76 mm) LED black trim.
        3. Car Lighting: 4 – 3 inch (76 mm) LED brushed stainless steel trim.
        4. Car Lighting: 4 – 3 inch (76 mm) LED oil rubbed bronze trim.

** NOTE TO SPECIFIER ** Delete handrail not required.

        1. Handrails: 2 inches (51 mm) flat to match wall panel (standard).
        2. Handrails: 2 inches (51 mm) flat black.
        3. Handrails: 2 inches (51 mm) flat brushed stainless steel.
        4. Handrails: 2 inches (51 mm) flat oil rubbed bronze.
        5. Handrails: 1-/2 inches (38 mm) round clear mill aluminum.
        6. Handrails: 1-/2 inches (38 mm) round brushed brass.
        7. Handrails: 1-/2 inches (38 mm) round brushed stainless steel.
        8. Handrails: 1-/2 inches (38 mm) round oil rubbed bronze.
        9. Handrails: 2 inches (51 mm) flat solid Birch wood (standard).
        10. Handrails: 2 inches (51 mm) flat solid Oak wood (standard).
        11. Handrails: 2 inches (51 mm) flat solid Maple wood (upgrade).
        12. Handrails: 2 inches (51 mm) flat solid Cherry wood (upgrade).
        13. Handrails: 2 inches (51 mm) flat solid Mahogany wood (upgrade).
        14. Handrails: 2 inches (51 mm) flat solid Walnut wood (upgrade).

** NOTE TO SPECIFIER ** Delete operating features not required.

      1. Operating Features:
        1. Car Operating Panel: Panel with illuminated automatic controls, emergency stop switch, alarm button, Dot Matrix floor position/directional display, and integrated key pad phone.

** NOTE TO SPECIFIER ** Delete operating panel finish not required.

          1. Operating Panel Finish: Brushed stainless steel.
          2. Operating Panel Finish: Brushed brass.
          3. Operating Panel Finish: Oil rubbed bronze.

** NOTE TO SPECIFIER ** Delete lock options not required.

          1. Operating Panel: Keyed lock control panel.
          2. Operating Panel: Touch key pad.
        1. Hall Station: Panel with illuminated button provided at each landing.

** NOTE TO SPECIFIER ** Delete if not required.

          1. Provide key lock out.

** NOTE TO SPECIFIER ** Delete if not required.

          1. Provide upgrade dot matrix directional display (standard).

** NOTE TO SPECIFIER ** Delete finish not required.

          1. Finish: Brushed stainless steel.
          2. Finish: Brushed brass.
          3. Finish: Oil rubbed bronze.
        1. Pit Switch and car top run/stop switch.
        2. Uninterruptible power supply (UPS) for lowering and automatic gate operation (if equipped) in the event of a power failure.

** NOTE TO SPECIFIER ** Delete homing floor not required.

        1. Automatic Homing: Disabled.
        2. Automatic Homing: 1.
        3. Automatic Homing: 2.
        4. Automatic Homing: 3.
        5. Automatic Homing: 4.
        6. Automatic Homing: 5.
        7. Automatic Homing: 6.
        8. Control Panel Integrated telephone inside car.

** NOTE TO SPECIFIER ** Delete gate type not required.

        1. Gate Type with Safety Switch: Accordion.
        2. Gate Type with Safety Switch: Wrap around.
        3. Gate Type with Safety Switch: 2 speed.
        4. Gate Type with Safety Switch: 3 speed.

** NOTE TO SPECIFIER ** Delete hoistway door type not required.

        1. Hoistway Door Type: Swing (standard).

** NOTE TO SPECIFIER ** Delete hoistway swing door interlock not required.

          1. Interlock: Ivory (standard).
          2. Interlock: Brushed stainless steel (upgrade).
          3. Interlock: Oil rubbed Bronze (ORB) (upgrade).
          4. Interlock: Brass powder coat finish (upgrade).
          5. Interlock: GAL mechanical door locks (requires retiring cam upgrade).
        1. Hoistway Door Type: 2 speed (upgrade).
        2. Hoistway Door Type: 3 speed (upgrade).

** NOTE TO SPECIFIER ** Delete hoistway door finish not required. 2/3 SPD only.

        1. Hoistway Door Finish: Beige.
        2. Hoistway Door Finish: Brushed stainless steel.
        3. Upper and lower terminal limits.
        4. Final limits (2 upper and 1 lower – drum system only).
        5. Slack rope safety with manual reset switch.
        6. Anti-creep device.
        7. Minimum pressure switch – hydraulic system only.
        8. Pump run timer – hydraulic system only.
        9. Drive circuit disconnect box (with auxiliary contacts) at controller.
        10. Light circuit disconnect box at controller.

** NOTE TO SPECIFIER ** Delete gate operator not required.

        1. Automatic Gate Operator: Automatic gate opener.
        2. Automatic Gate Operator: Without automatic gate opener.
        3. Automatic Gate Operator: 2 speed door (included).
        4. Automatic Gate Operator: 3 speed door (included).

** NOTE TO SPECIFIER ** Delete if not required.

        1. Provide tank heater.

** NOTE TO SPECIFIER ** Delete if not required.

        1. Buffer springs required for pits over 15 inches (381 mm).

** NOTE TO SPECIFIER **  Delete if not required.

        1. Supplemental Safety Device: Light beam on car (upgrade).

** NOTE TO SPECIFIER **  Delete if not required.

        1. Supplemental Safety Device: Space guard for each landing door (recommended with accordion gates).
        2. Guide Rail: Dual 8 lbs. modular machined steel T-rail system.
        3. Wire Rope: Two 3/8 inch (9.5 mm) diameter 8 x19 ga. aircraft wire ropes.
        4. Sling: 1/4 inch (6 mm) and 12 ga. structural and formed steel plates.
        5. Platform Floor: Unfinished plywood with removable insert for 3/4 inch (19 mm) flooring.
        6. Finishes: Components shall be prepared with galvanized coating or electrostatically applied and baked thermostatic powder coat finish.

** NOTE TO SPECIFIER ** Delete if not required.

    1. RESIDENTIAL ELEVATOR – TRANSCEND SERIES
      1. System: Provide Transcend Series home elevator by Rock Mountain Elevator Products.
      2. Characteristics:

** NOTE TO SPECIFIER ** Delete drive system not required.

        1. Drive System: Provide a hydraulic system (SRH).
        2. Drive System: Provide a machine room less hydraulic system (MRL).
        3. Drive System: Provide a floor mount winding drum system (RMR).
        4. Drive System: Provide a machine room less winding drum system (RMD).

** NOTE TO SPECIFIER ** Delete stops not required.

        1. Number of Stops: 2.
        2. Number of Stops: 3.
        3. Number of Stops: 4.
        4. Number of Stops: 5.
        5. Number of Stops: 6.

** NOTE TO SPECIFIER ** Delete car configuration not required.

        1. Car Configuration: Front – enter and exit same side.
        2. Car Configuration: Front and Rear – enter and exit opposite sides.
        3. Car Configuration: Front and Side – enter and exit 90 degree adjacent sides.

** NOTE TO SPECIFIER ** Specify maximum travel up to 50 feet (15.24 m)

        1. Maximum Travel: ___.

** NOTE TO SPECIFIER ** Delete rated load not required. 1400 pound capacity may require local code variance.

        1. Rated Load: 750 pounds (340Kg).
        2. Rated Load: 950 pounds (430 Kg).
        3. Rated Load: 1400 pounds (635 Kg).
        4. Rated Speed: 40 FPM (12.2 MPM).

** NOTE TO SPECIFIER ** Delete car size not required.

        1. Car Size: 36 inches W x 48 inches D (914 mm x 1219 mm).
        2. Car Size: 36 inches W x 60 inches D (914 mm x 1524 mm).
        3. Car Size: 40 inches W x 54 inches D (1016 mm x 1372 mm).
        4. Car Size: 42 inches W x 60 inches D (1067 mm x 1524 mm).

** NOTE TO SPECIFIER ** Delete car height not required.

        1. Car Height: 80 inches (2032 mm).
        2. Car Height: 84 inches (2134 mm).
        3. Car Height: 96 inches (2438 mm).

** NOTE TO SPECIFIER ** Delete car wall panel and material not required.

        1. Car Walls:
          1. Aluminum framing with Glass upper and lower panels. Laminated safety glass with low profile pattern on each glass panel.
        2. Car Walls: Custom. Refer to Drawings

** NOTE TO SPECIFIER ** Delete panel material not required.

          1. Panel Material: Glass.
          2. Panel Material: Acrylic.
          3. Panel Material: Mirror.
          4. Panel Material: Faux wrought iron.
          5. Panel Material: Wire mesh.
          6. Panel Material: Copperleaf.

** NOTE TO SPECIFIER ** Delete glass panel not required.

          1. Panel: Half wall.
          2. Panel: Full wall.
          3. Panel: Custom insert panel. Refer to drawings.

** NOTE TO SPECIFIER ** Delete glass panel location not required.

          1. Panel Location: Strike.
          2. Panel Location: Rail wall.
          3. Panel Location: Return.
          4. Panel Location: Rear wall.
          5. Panel Location: Custom panel. Refer to drawings.
        1. Car Walls: Rustic.

** NOTE TO SPECIFIER ** Delete panel not required.

          1. Panel: Mine Shaft model.
          2. Panel: Mesh panel inserts.
          3. Panel: Mesh and glass inserts. Refer to drawings.

** NOTE TO SPECIFIER ** Delete ceiling not required.

        1. Ceiling: Flat panel with two lights. Match car panels (standard).
        2. Ceiling: Flat panel with four lights. Match car panels (upgrade).
        3. Ceiling: Single tray with crown molding and two lights.
        4. Ceiling: 4 panel with crown molding and 4 lights centered in each panel.
        5. Ceiling: Single tray with crown molding and two lights.

** NOTE TO SPECIFIER ** Delete car lighting standard options not required.

        1. Car Lighting: 2 – 3 inch (76 mm) LED white trim.
        2. Car Lighting: 2 – 3 inch (76 mm) LED black trim.
        3. Car Lighting: 2 – 3 inch (76 mm) LED brushed stainless steel trim.
        4. Car Lighting: 2 – 3 inch (76 mm) LED oil rubbed bronze trim.

** NOTE TO SPECIFIER ** Delete car lighting upgrade options not required.

        1. Car Lighting: Flat panel translucent LED.
        2. Car Lighting: Curved panel translucent LED.
        3. Car Lighting: 6 flush brushed stainless steel fluorescent.
        4. Car Lighting: 4 – 3 inch (76 mm) LED white trim.
        5. Car Lighting: 4 – 3 inch (76 mm) LED black trim.
        6. Car Lighting: 4 – 3 inch (76 mm) LED brushed stainless steel trim.
        7. Car Lighting: 4 – 3 inch (76 mm) LED oil rubbed bronze trim.
        8. Car Lighting: 6 – 1 inch (25 mm) Linvisidots.
        9. Car Lighting: 6 – 2 inches (51 mm) square fluorescents.

** NOTE TO SPECIFIER ** Delete handrail not required.

        1. Handrails: 2 inches (51 mm) flat (match wall panel).
        2. Handrails: 2 inches (51 mm) flat brushed brass.
        3. Handrails: 2 inches (51 mm) flat clear mill aluminum.
        4. Handrails: 2 inches (51 mm) flat brushed stainless steel.
        5. Handrails: 2 inches (51 mm) flat oil rubbed bronze.
        6. Handrails: 1-1/2 inches (38 mm) round clear mill aluminum.
        7. Handrails: 1-1/2 inches (38 mm) round brushed brass.
        8. Handrails: 1-1/2 inches (38 mm) round brushed stainless steel.
        9. Handrails: 1-1/2 inches (38 mm) round oil rubbed bronze.

** NOTE TO SPECIFIER ** Delete operating features not required.

      1. Operating Features:
        1. Car Operating Panel: Panel with illuminated automatic controls, emergency stop switch, alarm button, Dot Matrix floor position/directional display, and integrated key pad phone.

** NOTE TO SPECIFIER ** Delete operating panel finish not required.

          1. Operating Panel Finish: Brushed stainless steel.
          2. Operating Panel Finish: Brushed brass.
          3. Operating Panel Finish: Oil rubbed bronze.

** NOTE TO SPECIFIER ** Lock options to limit access or use. Delete lock not required.

          1. Operating Panel: Keyed lock control panel.
          2. Operating Panel: Touch key pad.

** NOTE TO SPECIFIER ** Delete COP style not required.

          1. COP/Hall Station Style: Standard.
          2. COP/Hall Station Style: Vintage.
          3. COP/Hall Station Style: Victorian.
          4. COP/Hall Station Style: Round.
          5. COP/Hall Station Style: Gothic.
        1. Hall Station: Panel with illuminated button provided at each landing.

** NOTE TO SPECIFIER ** Delete if not required.

          1. Provide key lock out.
          2. Provide dot matrix directional display (Standard).

** NOTE TO SPECIFIER ** Delete finish not required.

          1. Finish: Brushed stainless steel.
          2. Finish: Brushed brass.
          3. Finish: Oil rubbed bronze.
        1. Pit Switch and car top run/stop switch.
        2. Uninterruptible power supply (UPS) for lowering and automatic gate operation (if equipped) in the event of a power failure.

** NOTE TO SPECIFIER ** Delete homing floor not required.

        1. Automatic Homing: Disabled.
        2. Automatic Homing: 1.
        3. Automatic Homing: 2.
        4. Automatic Homing: 3.
        5. Automatic Homing: 4.
        6. Automatic Homing: 5.
        7. Automatic Homing: 6.
        8. Control Panel Integrated telephone inside car.

** NOTE TO SPECIFIER ** Delete gate type not required.

        1. Gate Type with Safety Switch: Accordion.
        2. Gate Type with Safety Switch: Wrap around.
        3. Gate Type with Safety Switch: 2 speed three panel – stacking.
        4. Gate Type with Safety Switch: 3 speed three panel – stacking..

** NOTE TO SPECIFIER ** Delete hoistway door type not required.

        1. Hoistway Door Type: Swing – no trim (standard – option ‘B’).
        2. Hoistway Door Type: Frameless glass swing (by others).

** NOTE TO SPECIFIER ** Delete hoistway swing door interlock not required.

          1. Interlock: Ivory (standard).
          2. Interlock: Oil rubbed bronze (ORB) (upgrade).
          3. Interlock: Brushed stainless steel (upgrade).
          4. Interlock: Brass powder coat finish (upgrade).
          5. Interlock: GAL mechanical door locks (requires retiring cam upgrade).
        1. Hoistway Door Type: 2 speed (upgrade).
        2. Hoistway Door Type: 3 speed (upgrade).

** NOTE TO SPECIFIER ** Delete hoistway door finish not required. 2/3 SPD only

        1. Hoistway Door Finish: Beige.
        2. Hoistway Door Finish: Brushed stainless steel.
        3. Upper and lower terminal limits.
        4. Final limits (2 upper and 1 lower – drum system only).
        5. Slack rope safety with manual reset switch.
        6. Anti-creep device.
        7. Minimum pressure switch – hydraulic system only.
        8. Pump run timer – hydraulic system only.
        9. Drive circuit disconnect box (with auxiliary contacts) at controller.
        10. Light circuit disconnect box at controller.

** NOTE TO SPECIFIER ** Delete gate operator not required.

        1. Automatic Gate Operator: Automatic gate opener.
        2. Automatic Gate Operator: Without automatic gate opener.
        3. Automatic Gate Operator: 2 speed door (included).
        4. Automatic Gate Operator: 3 speed door (included).

** NOTE TO SPECIFIER ** Delete if not required.

        1. Provide tank heater.

** NOTE TO SPECIFIER ** Delete if not required.

        1. Buffer springs required for pits over 15 inches (381 mm).

** NOTE TO SPECIFIER **  Delete if not required.

        1. Supplemental Safety Device: Light beam on car (upgrade).

** NOTE TO SPECIFIER **  Delete if not required.

        1. Supplemental Safety Device: Space guard for each landing door (recommended with accordion gates).
        2. Guide Rail: Dual 8 lbs. modular machined steel T-rail system.
        3. Wire Rope: Two 3/8 inch (9.5 mm) diameter 8 x19 ga. aircraft wire ropes.
        4. Sling: 1/4 inch (6 mm) and 12 ga. structural and formed steel plates.
        5. Platform Floor: Unfinished plywood with removable insert for 3/4 inch (19 mm) flooring.
        6. Finishes: Components shall be prepared with galvanized coating or electrostatically applied and baked thermostatic powder coat finish.
    1. ELECTRICAL SYSTEMS
      1. Coordinate requirements with the building electrical system:
        1. 4 HP, 230 VAC, 30 amp (60 amp for 5 HP systems), 60 Hz, single phase power source with neutral and ground (4 wires) in the controller area.
        2. 115 VAC, single phase, 20 amp, 60 Hz power circuit in the controller area for the car lights.
        3. Telephone circuit in the controller area.
  1.  EXECUTION
    1. EXAMINATION
      1. Do not begin installation until substrates have been properly constructed and prepared.
      2. Use field dimensions and approved manufacturer’s shop drawings to examine substrates, supports and other conditions under which this work is to be performed. Do not proceed with work until unsatisfactory conditions are corrected.
      3. If substrate preparation is the responsibility of another installer, notify Architect in writing of unsatisfactory preparation before proceeding.
    2. PREPARATION
      1. Clean surfaces thoroughly prior to installation.
      2. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
    3. INSTALLATION
      1. Install in accordance with manufacturer’s instructions approved submittals and in proper relationship with adjacent construction. The home elevator shall be installed in accordance with manufacturer’s instructions and as specified and approved by architect. Coordinate with hoistway doors installed by the Contractor.
    4. FIELD QUALITY CONTROL
      1. Field Inspection: Coordinate field inspection in accordance with appropriate sections in Division 01.

** NOTE TO SPECIFIER ** Include if manufacturer provides field quality control with onsite personnel for instruction or supervision of product installation, application, erection or construction. Delete if not required.

      1. Manufacturer’s Services: Coordinate manufacturer’s services in accordance with appropriate sections in Division 01.
      2. The elevator contractor shall make a final check of the elevator’s operation with the Owner or Owner’s representative present prior to turning the elevator over for use. The elevator contractor shall determine that operating and safety devices are functioning properly.
    1. CLEANING AND PROTECTION
      1. Clean products in accordance with the manufacturer’s recommendations.
      2. Touch-up, repair or replace damaged products before Substantial Completion.